If a tool operates in both directions, can one set of clockwise results represent both directions?
Applies to: ISO 6789-1:2017, ISO 6789-2:2017 · Updated 2026-11-26
Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND
No. Where torque performance in both directions needs to be demonstrated, each direction must be measured separately; clockwise results support only the direction that was measured. A ratchet that can switch direction does not by itself show that the manufacturer declares the same torque performance in both directions. First confirm the tool’s specified operating directions, then check which directions the documents cover.
Confirm the specified operating directions even if the mechanism is reversible
When you pick up a wrench with a direction switch, it is easy to read “it can drive in reverse” as “it gives the same torque results in reverse.” During inspection, keep these two things apart: what the mechanism can do depends on the product design; which directions carry the manufacturer’s declared measurement performance depends on its specifications and documents.
The Part 1 requirement on maximum permissible relative deviation states that, if a tool operates in both directions, the maximum permissible relative deviation must be met in each direction specified by the manufacturer. The measurement procedure also requires each direction to be measured separately. A clockwise result that conforms therefore cannot be used to infer that counterclockwise also conforms; changing the sign of a clockwise value does not turn it into measurement evidence for the other direction.
Marking the direction on the tool itself is subject to its own condition: the direction of operation must be marked on tools capable of operating in one direction only. This does not mean that a tool without an arrow on its body can be asserted to have torque performance in both directions. For a tool with unclear direction information, first confirm the specified directions with the supplier rather than treating its appearance as a performance statement.
Match each set of results to its direction
On receipt, first find the direction field in the declaration of conformance or calibration certificate, then check the measurement data for that direction. Both the Part 1 declaration and the Part 2 certificate require the direction of operation to be stated; beyond the direction being named, you also need to be able to see which results belong to which direction.
| What the document shows | What it can support |
|---|---|
| Only clockwise and its results | Supports the clockwise measurement shown; evidence for counterclockwise is still missing |
| Identifiable results for both directions | The measurements for each direction can be checked separately |
| States both directions, but gives only one set of figures without a direction | First ask which direction the data belong to; do not yet presume that both directions have been completed |
If the actual work requires only clockwise operation, check the evidence for that direction as needed; if counterclockwise is required, first confirm that the tool is suitable, then arrange the corresponding measurements. The table provides guidance for checking documents on receipt; it does not mean that any document with a missing field is automatically invalid. Under Part 2, calibration follows the Part 1 measurement method, and it does not change direction-by-direction measurement into one direction representing all.