How is the relative measurement error calculated in Part 2?
Applies to: ISO 6789-2:2017 · Updated 2026-11-23
Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND
In Part 2, the relative measurement error is the target value on the tool side minus the reference value from the measurement device, divided by the reference value and multiplied by 100 %. The formula is a_s = (X_a − X_r) ÷ X_r × 100. This is the percentage for one calibration result, and the denominator must be the reference value from the same result.
First, separate the tool side from the reference side
Depending on the tool’s Type and Class, X_a can be the indicated value, the set value, or the nominal value; X_r is the reference value provided by the measurement device. Before entering values into the formula, confirm the role of each data field and convert the torque values to the same unit.
For example, for an adjustable, graduated Type II Class A wrench, the torque set on the scale is the tool-side X_a, and the torque obtained by the measurement device at release is X_r. The number on the device is not the target the tool was originally meant to reach; the two fields must not be swapped just because the device value is also a “reading.”
The formula in subclause 5.1 of Part 2 preserves this difference in roles: subtract the reference side from the tool side, then use the reference side as the basis of the percentage. Spreadsheet column headings such as “Torque 1” and “Torque 2” are often not enough to check whether the formula has been applied correctly.
Calculating with one set of teaching data
The following is teaching data: suppose the wrench above is set to 60 N·m within its specified range, and at one release the measurement device gives a reference value of 61.8 N·m. This result uses X_a = 60 N·m and X_r = 61.8 N·m.
a_s = (60 − 61.8) ÷ 61.8 × 100
= −1.8 ÷ 61.8 × 100 ≈ −2.913 %
Three decimal places are shown here for teaching purposes only; this does not specify a rounding rule for every certificate. The denominator is 61.8. If 60 is used instead, the result is no longer the Part 2 relative measurement error for this result.
What the minus sign means here
A negative value means that the target value on the tool side is lower than the reference value provided by the measurement device. In this example the setting is 60 N·m, but the device observed a larger 61.8 N·m, which gives a negative error. A minus sign does not automatically mean that the torque actually delivered was low.
Likewise, this minus sign does not indicate the direction of rotation. Clockwise or counterclockwise operation should be confirmed from the record of the measurement direction, while the sign of the error is read from the subtraction of the values.
This single a_s is not the mean error for a calibration point, and still less is it the measurement uncertainty. Keep the individual data, then handle the mean and the uncertainty according to the Part 2 methods. For a Part 1 deviation decision, use the Part 1 definitions and formula instead; this value cannot be used directly as a_d.