What does measurement uncertainty describe?

Applies to: ISO 6789-2:2017 · Updated 2026-11-23

Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND

Key answer

Measurement uncertainty describes how much doubt remains about a calibration result; measurement error describes how far the tool value differs from the reference value. The two need to be read together. A small error does not mean that the uncertainty is also small, and uncertainty is not an allowance for how far the tool may depart from its target.

Seeing the difference in one calibration reading

Suppose an indicating torque tool, at a calibration point with a target value of 50.0 N·m, indicates 50.0 N·m while the measurement device provides a reference value of 49.0 N·m. This is teaching data, not a measured result. Using the Part 2 method for the relative measurement error:

Difference between tool value and reference value = 50.0 − 49.0 = +1.0 N·m.

a_s = (50.0 − 49.0) ÷ 49.0 × 100 ≈ +2.04 %.

The plus sign means that the tool’s indicated value for this result is higher than the reference value. Once the difference is known, questions remain: how finely can the reading be resolved, how widely do repeated measurements scatter, and how much do mounting and the force-loading arrangement contribute? These are the questions an uncertainty evaluation has to address. This one data point alone is not enough to calculate a complete uncertainty.

Where uncertainty comes from

In the calibration context, Part 2 considers the tool’s resolution, repeatability, and reproducibility, as well as the effects of the output drive, the interface, and the force loading point; components from the measurement device are also included when combining. How each one is obtained depends on the tool type and the applicable method; a single reading cannot fill in every field.

For example, if readings at the same setting are very close to each other, that supports a judgment of good repeatability. But if the results change after the tool is remounted, there is another effect to evaluate. Stable readings are therefore only part of the evidence and do not mean the whole result is free of uncertainty.

A calibration certificate lists the relative expanded measurement uncertainty W and the relative measurement uncertainty interval W′ for each calibration point. They are made up differently, so the two columns cannot be exchanged, and it is unwise to extract a single percentage without the calibration point and the name of the quantity it belongs to.

Does it represent every effect in use?

This evaluation corresponds to the calibration conditions. Once the tool is in use on site, the way it is used or configured may bring additional effects; the Introduction to Part 2 also notes that uncertainty in use may have other sources.

When reading the results, first confirm the tool identification, measurement direction, calibration point, and accessory configuration, then take both the error and the uncertainty into account when evaluating fitness for the intended use. The example in this article only teaches you to distinguish the two kinds of information. It does not judge the tool to conform, nor does it guarantee that the tool will perform the same way under every working condition.