What is the permissible deviation for torque tools in the 2017 edition?

Applies to: ISO 6789-1:2017 · Updated 2026-11-17

Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND

Key answer

In ISO 6789-1:2017, the permissible deviation is selected by tool Type, Class, and maximum torque; not every tool can be treated as ±4 %. This limit is called the “maximum permissible relative deviation,” and it is used to check each result obtained by the specified procedure. If the manufacturer claims a smaller value, conformance must also be judged against that claim.

Check the classification first, then the maximum torque

When you receive a catalog or measurement record, first identify the Type and Class. Type I is an indicating tool and Type II is a setting tool; a product name such as “torque wrench” or “torque screwdriver” alone is not enough to select the value. The same class letter represents different tools in different Types, and the tolerance may also differ.

Under subclause 5.1.5, the lookup can first be split into two paths:

  • Classes not affected by the 10 N·m boundary: Type I Classes A and D, and Type II Classes D, E, F, and G; the tabulated value is ±6 % in every case.
  • Classes that depend on maximum torque: Type I Classes B, C, and E, and Type II Classes A, B, and C; ±6 % when the maximum torque is not more than 10 N·m, and ±4 % when it is more than 10 N·m.

The maximum torque here is a tool specification, not the test point. After selecting the percentage, calculate the relative deviation from each measurement point’s target value. Nor should the tool’s maximum torque be multiplied by the percentage to produce a fixed torque difference shared across the whole range.

One tool shows how the value is selected

The following is teaching data: suppose a Type II Class A adjustable, graduated wrench has a specified range of 20–100 N·m, and the manufacturer makes no claim of a smaller deviation. Because the maximum torque of 100 N·m is greater than 10 N·m, ±4 % applies.

At a target value of 20 N·m, the corresponding allowance is 20 × 4 ÷ 100 = 0.8 N·m, so the observed-value limits are 20 ± 0.8, that is, 19.2–20.8 N·m. The percentage is based on that target value. This only illustrates how to read one measurement point; it does not complete conformance testing of the whole tool.

What else to check once you have the limit

First confirm that the measurement point lies within the tool’s specified range, then calculate and compare each result individually. If the tool operates in both directions, each direction specified by the manufacturer must meet the requirement; results in one direction cannot stand in for the other.

When receiving tools, it is advisable to check the classification, maximum torque, applicable directions, and the limit actually used together. Where the manufacturer claims a smaller value, also confirm which value the measurement records and the declaration of conformance use. Finding “±4 %” in a catalog does not by itself support the conclusion that the tool has passed testing.