Does the 10 N·m boundary in the tolerance tables refer to maximum torque or the test point?

Applies to: ISO 6789-1:2017 · Updated 2026-11-17

Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND

Key answer

The 10 N·m boundary refers to the tool’s maximum torque, not the test point. First confirm whether the Type and Class need a column choice at all, then choose the column by the tool’s maximum torque. Measuring the same tool at a lower torque point does not automatically switch it to a wider tolerance.

Why a low measurement point does not mean the left column

The tolerance tables in ISO 6789-1:2017 divide the tools that need distinguishing into two groups by “maximum torque”: not more than 10 N·m, and more than 10 N·m. The division separates tool specifications; it does not group the individual measurement points within a test.

The following is teaching data (assumed specifications): a Type II Class A wrench has a lowest marked value of 10 N·m and a maximum value of 50 N·m. When it is measured at its lowest point of 10 N·m, ±4 % is still selected on the basis of the 50 N·m maximum value; ±6 % cannot be used just because the target value equals 10 N·m.

Another tool of the same class whose maximum value is itself 10 N·m falls into the “not more than 10 N·m” group, with a tabulated tolerance of ±6 %. So even when two tools are both measured at 10 N·m, the applicable percentage can differ.

First confirm whether this class needs a column choice

For Type I Classes B, C, and E and Type II Classes A, B, and C, the column is selected according to the tool’s maximum torque. For these classes, a maximum value of exactly 10 N·m falls under ±6 %, and only a maximum greater than 10 N·m falls under ±4 %; the equality at the boundary must not be dropped.

Type I Classes A and D and Type II Classes D, E, F, and G are tabulated at ±6 % throughout, and do not change to ±4 % when the maximum value exceeds 10 N·m. “High-torque tools are always ±4 %” is therefore not a reliable way to look up the value either. If the manufacturer claims a smaller deviation, that claimed value must be used.

Look at the current target value only after choosing the percentage

Returning to the hypothetical wrench in the teaching data, with a maximum value of 50 N·m, and assuming no smaller claim, the allowance at a target value of 10 N·m is 10 × 4 ÷ 100 = 0.4 N·m; the observed-value limits are 10 ± 0.4, that is, 9.6–10.4 N·m.

Keep the two uses distinct: the maximum value selects the tolerance percentage, and the current target value is used to calculate the relative deviation and the corresponding torque limits. When checking a spreadsheet, verify the source of each of these two fields separately, so that a measurement point is not used to choose the column and the maximum value is not used as the denominator of the deviation formula.