From what torque can a torque tool be used?

Applies to: ISO 6789-1:2017 · Updated 2026-11-17

Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND

Key answer

Under ISO 6789-1:2017, first confirm the tool’s class: some classes start from the lowest marked value, while for others the manufacturer specifies the range or torque value. To decide whether a working torque is covered, check the tool markings and the manufacturer’s information. The lower limit cannot be set across the board by multiplying the maximum value by 20 %.

Use the class to find the basis for the lower end

The specified torque range is the interval covered by the requirements and methods of ISO 6789-1. The table below is reorganized around “where to find the lower limit”; it is not meant for picking a row directly from whether the tool appears to have a scale.

Basis for the lower endApplicable classesWhat to check in practice
From the lowest marked value to the tool’s maximum torque valueType I A, B, D; Type II A, D, GThe specified lower and upper limits marked on the tool
Range or value specified by the manufacturerType I C, E; Type II B, C, E, FThe specification for that model, the setting conditions, and the range or fixed value

For example, if a wrench is known to be a Type I Class C electronic measurement wrench, look up the manufacturer’s specification. Do not treat a very small number as the specified lower limit just because the display can show it. For another tool in Type II Class A, confirm the lowest marked value instead of applying a customary percentage.

A zero position does not mean coverage starts from zero

The scales or dials of Type I Class A, B, and D indicating tools have a zero position, mainly so the user can identify where zero is. ISO 6789-1:2017 also requires the non-specified region between zero and the lowest specified torque value to be clearly marked on or near the scale or dial, or the specified range to be identified to the user in another way. Type I Classes C and E have a corresponding requirement: the region between zero and the lower limit specified by the manufacturer must likewise be identified in some way so the user can recognize that it is not within the specified range.

When reading a scale, therefore, look at the zero position, the non-specified region, and the marking that shows where the valid range begins together. A visible scale mark, a moving pointer, or a reading on a display is not, on its own, enough to prove that a point lies within the specified range. If the markings and the catalog contradict each other, first ask the manufacturer to clarify the corresponding model and conditions.

For fixed-adjustment tools, check that value

Type II Classes B and E are fixed-adjustment tools, and the marking on the tool corresponds to the fixed torque value. Do not imagine an interval from which any value can be chosen. For adjustable tools, check the range marking and instructions, and confirm that the torque required for the job lies within the range.

The range or fixed value on the tool, in the specification documents, and in the declaration of conformance can be checked against one another. What this establishes is the range covered by the declaration, not a complete assessment of the tool’s current condition; actual use still requires appropriate operating conditions and measurement evidence. If the working point is below the specified lower limit, first confirm whether other information supports that use, or choose a tool with a suitable range.