Is a torque tool always unusable below 20 % of its maximum torque?
Applies to: ISO 6789:2003, ISO 6789-1:2017 · Updated 2026-11-17
Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND
Not necessarily: 20 % is the lower limit of the specified measuring range in the 2003 edition, while ISO 6789-1:2017 determines the lower limit by tool class. Whether a value below one fifth of the maximum lies within the specified range depends on the edition, the classification, and the tool’s information; a single percentage cannot decide it.
The same 20 %: first confirm which edition you are reading
The 2003 edition sets the range covered by its requirements and test methods at 20 %–100 % of the maximum torque value. This describes which range the edition’s general provisions support; it does not declare that every tool necessarily fails below one fifth.
ISO 6789-1:2017 instead works by class. Type I Classes A, B, and D and Type II Classes A, D, and G run from the lowest marked value to the tool’s maximum value. Type I Classes C and E and Type II Classes B, C, E, and F use the range or value specified by the manufacturer. You therefore cannot treat 20 % as the universal 2017 lower limit, nor, conversely, say that every tool under the 2017 edition can be used below 20 %.
A hypothetical tool shows the difference
The following is teaching data: suppose a Type II Class A tool under ISO 6789-1:2017 has a lowest marked value of 16 N·m and a maximum value of 160 N·m.
One fifth of the maximum is 160 × 20 % = 32 N·m; the lowest marked value as a proportion of the maximum is 16 ÷ 160 × 100 % = 10 %. Under the 2017 rule for this class, the range starts at 16 N·m, and that value need not be excluded just because it is below 32 N·m.
If the same figures are interpreted under the general range rule of the 2003 edition, the range is 32–160 N·m. This comparison only shows that the two editions’ rules differ. It does not mean that changing the edition year extends the guarantee for the same real tool, nor that the hypothetical tool above has passed testing.
What really needs confirming is the basis for the low point
First find the full edition and the Type/Class, then check whether the tool markings, the catalog, and the corresponding documents agree. If the information gives only the maximum value, or you only see that the display can show a certain low number, that is still not enough to establish that the point is covered.
The 2017 edition has separate identification requirements for the region between zero and the specified lower limit for both Type I Classes A, B, and D and Type I Classes C and E. This is also a reminder that “a number is visible” and “within the specified range” are two different things. For fixed-adjustment tools, check the fixed value instead of assuming an adjustable interval.
When the working point lies outside the confirmed range, obtain additional information that supports that use, or choose a tool with a suitable range. Even within the range, the actual measurement evidence and conditions of use still need to be checked; a percentage on its own makes no conformance decision for any tool.