How should ISO 6789 terms and symbols be read?

Applies to: ISO 6789:2003, ISO 6789-1:2017, ISO 6789-2:2017 · Updated 2026-11-23

Technical review: Alston Hsiao (Chieh-Jen Hsiao), CTO, STAND

Key answer

First confirm the edition, then check which object and which kind of result a symbol refers to; deviation, measurement error, and uncertainty must not be mixed up just because they are all written as percentages. Data for the same tool can contain all of these quantities at once, and understanding their names and purposes matters more than memorizing the formulas first.

Find an explanation from the term you encountered

Question that came up while reading a documentWhat to distinguish firstFurther reading
A catalog calls a percentage “accuracy”The concept of accuracy versus the numerical requirement of the maximum permissible relative deviationHow should a catalog’s “accuracy ±4 %” be understood under the standard?
A table shows a_d, a_s, or the 2003 edition’s AsThe roles of the quantities, the denominators, and the signs in each editionAre the percentage formulas in Part 1 and Part 2 interchangeable?
Why is an uncertainty listed when the error is small?The difference already calculated versus the doubt that still remains about the resultWhat does measurement uncertainty describe?
A calculation sheet shows w, W, and W′The relative standard measurement uncertainty, the relative expanded measurement uncertainty, and the relative measurement uncertainty intervalWhat do w, W, and W′ mean?

Read symbols together with their object and unit

When you see “reference value,” first check which device it comes from; when you see “target value,” first check whether it is the tool’s indicated value, its set value, or the nominal value for the applicable Class. X_t / X_o in Part 1 and X_a / X_r in Part 2 each have their own definitions; table columns in the same position must not be treated as the same calculation.

The 2003 edition uses “calibration device,” whereas the 2017 edition has the “measurement device” and the “measurement system / calibration system,” which includes the loading system. When reading data across editions, keeping each edition’s original wording and confirming the actual setup helps you tell whether a requirement applies to the tool, the device, or the whole system.

Throughout this article the physical quantity is called torque, expressed in N·m — the same word used in tool names such as “torque wrench” and “torque screwdriver.” A percentage should always be understood together with the value it is relative to. These are reading aids; they do not merge the definitions of different editions into a single set.

This article only provides entry points. When you need to check values or calculations, follow the table to the corresponding question, then verify against the part and year stated on the document, rather than letting a glossary take the place of each edition’s technical requirements.